Specifications
- ISO 9060:2018 Class C (previously known as second class)
- Power Supply 5.5 to 24 V DC
- Current Draw 10 µA
- Sensitivity 2.5 mV per W mˉ²
- Calibration Factor 2.5 W mˉ² per mV (reciprocal of sensitivity)
- Calibration Uncertainty ± 5 %
- Calibrated Output Range 0 to 5 V
- Measurement Repeatability Less than 1 %
- Non-stability (Long-term Drift) Less than 2 % per year
- Non-linearity Less than 1 % (up to 2000 W mˉ², maximum radiation measurement is 2000 W mˉ²)
- Response Time Less than 1 ms
- Field of View 180Ëš
- Spectral Range 360 to 1120 nm (wavelengths where response is 10 % of maximum) Directional (Cosine)
- Response ± 5 % at 75˚ zenith angle
- Temperature Response 0.04 ± 0.04 % per C
- Operating Environment -40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of 30 m
- Dimensions 24 mm diameter, 33 mm height
- Mass (with 5 m of cable) 90 g
- Warranty 4 years against defects in materials and workmanship
Ordering information
SP-215-SS