YSI 5200A Continuous Monitor

YSI 5200A Continuous Multiparameter RAS Monitor

Designed specifically for Aquaculture Systems, the YSI 5200 and AquaManagerâ„¢ Software integrate process control, alarming, and data management into one product. Simple enough to monitor one tank, powerful enough to manage a full scale farming operation from anywhere in the world. Simultaneously measure dissolved oxygen, pH, conductivity, ORP, salinity and temperature.

Add to Request

Engineered specifically for recirculating aquaculture systems, the YSI 5200A continuous monitor and AquaManager® Software can be used to integrate process control, feeding, alarming, and data management into one product or can be used to simply monitor one tank. Powerful enough to manage a full scale farming operation from anywhere in the world yet simple enough for anyone to use.

Access your facilities water quality data at any time with the Aquaviewer App from the App Store.

•Multi-parameter monitor: DO, Temperature, Conductivity, pH, ORP, Salinity
•Ethernet TCP/IP or wireless communications
•Event logging records calibrations, high and low conditions and more
•Conditional feed timer with Feed SmartTM software included
•Networking capability up to 32 instruments per comm port or can be integrated with 5400 MultiDO monitors
•Graphic, backlit LCD – quick, reliable system status checks
•Plug-and-play…easy to install and maintain with user-scalability – no need to hire consultants
•Flexible monitoring and control software
•E-mail and SMS alarming

Feed Smart software manages food delivery based on user-selectable inputs to manage feed delivery based on number of daily feedings, daily feed weights, total biomass and FCRs, along with parameter control based on water quality values. interfaces with most auto feeders.

Two versions are available:
5200A-DC
•12 VDC
•Wall mount bracket
5200A-AC
•100-240 VAC
•Wall mount bracket
•115 VAC U.S. power supply

Timers 4 timers – 10 events cascading events start/duration
1 feed timer channel (feeder not included); Feed Smart software manages feed delivery, user-selectable inputs for number of daily feedings, daily feed weights, total biomass, FCRS and parameter control
Temperature Operating -15 to +70°C (5 to 158°F); direct outside conditions with NEMA 4X enclosure
Communications RS-485 and RS-232 standard; Ethernet and wireless optional

Inputs
DO, pH, ORP, conductivity, temperature
2 user-configurable inputs, digital (0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA)

Output Relays
4 each 10 amp 115 VAC (5 amp 230 VAC) relays for parameter, control and/or alarm
E-mail and/or SMS alarming up to 3 e-mails with Ethernet module or up to 10 e-mails with AquaManager

Software AquaManager®; Windows 2000/XP/Vista/Windows 7 operating systems
Memory/Logging Non-volatile; 1000 data, 1250 relay/alarm, 1000 entries/change and 500 GLP records
Warranty 2-years instrument; 1-year probes and cable
Display Back-lit graphic LCD (320 x 240) with timer, extended temperature range LCD
Ratings NEMA 4X, CE, ULC, CUL, ETL, RoHS, IP-65, Made in USA
Field Upgradeable Software Yes; flash based

AquaManager desktop software provides the ability to instantly see an overview of your facility, manage parameter set points, and conveniently manage data to make informed operation decisions.

Ordering Information:

5200A-DC Multiparameter Aquaculture Monitor 12VDC
5200A-AC Multiparameter Aquaculture Monitor 110-230VAC

605953-010 10 M Cable Galvanic mg/l DO
605953-020 20 M Cable Galvanic mg/l DO
605953-030 30 M Cable Galvanic mg/l DO
605953-004 4 M Cable Galvanic mg/l DO
Cable Galvanic mg/l DO up to 100 Meters
605952-010 10 M Cable Galvanic mg/l DO and Temp
605952-020 20 M Cable Galvanic mg/l DO and Temp
605952-030 30 M Cable Galvanic mg/l DO and Temp
605952-004 4 M Cable Galvanic mg/l DO and Temp
Cable Galvanic mg/l DO and Temp up to 100 Meters
5561-10 10 M Cable with POL DO/Temp
5561-20 20 M Cable with POL DO/Temp
5561-30 30 M Cable with POL DO/Temp
5561-4 4 M Cable with POL DO/Temp
5562-10 10 M Cable with POL DO/Temp/Cond
5562-20 20 M Cable with POL DO/Temp/Cond
5562-4 4 M Cable and POL DO/Temp/Cond
X length SLP = Base price of 4 meter assembly + ( Length in meters * $6.00)

655900 Replacement POL DO Sensor
005564 pH Sensor Kit
005565 pH/ORP sensor Kit
005560 Conductivity, Temp Probe
603059 Flow Cell, Standard, 203 mL
005511 Probe Maintenance Kit, Polarographic
Probe Maintenance Kit, Galvanic
605285 RS-232 Opto Isolator
605935 Internal Serial to Ethernet Device Kit
Internal IP Phone Modem Kit
605204 DO Membrane Kit, 2 Mil Teflon (6 each includes electrolyte) (gray cap)
DO Membrane Kit, 2 Mil Teflon
DO Membrane Kit, 2 Mil Teflon
DO Probe Solution, 1 Pint
605307 Cap Membrane Kit 2.00 mil PE (6 each) includes electrolyte (blue cap)
655357 Probe Mounting Kit
006505 Weather Shield
006506 Desiccant Kit
006509 Rail Mount Kit
006510 Panel Mount Kit
065926UL Conduit Fitting, Large 1″ (for Optional Conduit Mount)
605227UL 12-Volt Power Supply, 115 VAC Input
655478UL 12-Volt Power Supply, 230 VAC Input
606100 230 VAC Cord, European
606101 230 VAC Cord, UK
606102 230 VAC Cord, Australia

655363 Software, AquaManager, Single and Network Use

5200a-continuous-multiparameter-monitor-2011

Weight 10 kg
Scroll to Top