Request list

is empty

You are here

Greenspan PS1000 Pressure Sensor DISCONTINUED

If you cannot find the part number in the documentation please provide detail. Specific to this item, it could include part number or application detail, (ex. 20 meters of cable, or 20 litres of volume)

The Enhanced features and performance of the new PS1000 pressure sensor provides users with an affordable solution to a wide range of water level and pressure monitoring applications. The PS1000 has a standard, 2 wire, loop powered 4-20mA output with an option for 0-2.5Vdc. New features include the ability to re-range the sensor, as well as adjust the fluid density and gravity to suit specific applications.

The PS1000 has a 0.1% FS Accuracy with a standard output of 4-20mA (0-2.5Vdc as an option)

Benefits
o Can be installed in active waters (acidic or salty) that would damage a stainless steel sensor.
o No need for regular desiccant replacement resulting in fewer field visits
o Low cost of ownership and minimal maintenance
o Ease of use and long term reliability

The Sensor is ideal for use in groundwater, surface water and wide range of water monitoring and environmental projects. A durable corrosion resistant body, rugged ceramic capacitance transducer and double O ring sealing ensure suitability for harsh environment applications. The sensor comes fitted with a moulded polyurethane cable as standard. Other cable options are also supported.

Features
• Loop powered - Battery or Solar
• 4-20mA or 0-2.5Vdc outputs
• 0.1% FS accuracy
• Field re-ranging and calibration
• User inputs for fluid density and Local gravity
• Double O-ring Design and moulded cable gland
• Acetyl construction
• ½” diameter ceramic capacitance transducer
• Long-term stability better than 0.2% per annum
• Optional SDI-12 adaptor for serial output
• Threaded fitting for Process connection.

An optional SDI-12 adapter can provide a serial output for external controllers or data loggers.

Applications
• Sewer wet well
• Borehole monitoring
• River and dam Level monitoring
• Floor warning Systems
• Tank level monitoring
• Process level and pressure monitoring.

The Sensor can be supplied in various gauge (vented) or absolute (non vented) pressure ranges. Gauge sensors utilise a closed vent system (CVS). This provides barometric pressure venting of the sensor, without the need to continually replace desiccant.

PS1000 Specification
Measurement technique ½” ceramic capacitance transducer

Std Ranges available
Gauge 2.5, 5, 10, 20, 40, 75, 100m
Absolute 20, 40, 75, 100m
Other ranges available Yes

Sensor output 4-20mA, or optional 0-2.5V dc (SDI-12 via adaptor)
Overall accuracy (combined linearity, hysteresis and repeatability) +/- 0.1% full Scale
Long-term stability 0.2%Xfull scale per annum

Cable type Polyurethane sheathed cable, OD 8mX, with 3mX vent tube, moulded entry, bare wire connection
Cable lengths 10, 20, 30, 50, 100, 150m (30, 65, 100, 165, 325,490 ft)
Closed Vent System (CVS) Gauge sensors must be fitted with a CVS

Power supply 8 to 30Vdc (at sensor) loop powered
Reverse polarity protection Yes
Surge current protected To 2kV
Warm-up time to stable reading <150 ms
Current consumption Up to 20mA while turned on, 0mA when off.

Operating temperature 0-50°C
Storage temperature -5°C - +60°C
Max Over pressure At least twice the full Scale range

Dimensions (L x OD) 315mm x 47mm (12.6” x 1.78”)
Weight 550g plus cable weight (665g per 10m length)
Wetted materials Acetyl, ceramic, 316 passivated stainless steel, polyurethane, viton

The PS1000 sensor is easy to install and provides user with a rugged and reliable solution to long term monitoring

Ordering Information:
700-1000 PS1000 PS1000 allows the ability to re-range the sensor with simple to use field adjust software.
The Following Information will be required:
1. Sensor full scale range (Specify range in m)
2. Sensor type (Gauge or Absolute)
3. Output required (4-20mA or 0-2.5V)
4. Moulded cable length (specify length in m)

Closed Vent System (for Gauge sensors)