The Solinst AquaVent Vented Water Level Datalogger records accurate water level and temperature measurements in shallow groundwater and surface water applications. It combines pressure and temperature sensors, hydrophobic filters and datalogger within a 7/8″ x 7″ (22 mm x 178 mm) stainless steel housing.
The AquaVent uses a gauged pressure transducer; it is open to the atmosphere via a vented cable to surface. Atmospheric pressure is applied to the transducer diaphragm, providing a cancellation effect for barometric pressure. This results in actual water level recordings. The vented cable and Solinst AquaVent logger are protected from moisture by built-in desiccants and hydrophobic filters.
The vented pressure transducer is made of Hastelloy®, making it extremely durable and accurate in a wide range of temperature and monitoring conditions. The sensor provides an accuracy of 0.05% FS, and can withstand 2 times over-pressure without permanent damage.
The robust FRAM memory can hold up to 120,000 data sets when programmed in Solinst Levelogger® Software with a compressed linear sampling mode.
AquaVent Applications
- Ideal for shallow applications: up to 65 ft (20 m) submergence
- Aquifer characterization: pumping tests, slug tests, etc.
- Stream gauging, lake and reservoir management
- Watershed, drainage basin and recharge monitoring
- Stormwater and runoff monitoring
- Long-term water level monitoring in wells and surface water
AquaVent Features
- Gauged pressure sensor for highly-accurate water level measurements: 0.05% FS
- Multiple built-in hydrophobic filters and desiccants – no need to replace, reducesAquaVent maintenance
- Easy-to-access, user-replaceable batteries in Wellhead
- Options for MODBUS (RS-232/RS-485) and SDI-12
- Separate cables for each communication protocol
- Use with Solinst software for multiple logging options including linear, event, and scheduled sampling
AquaVent Benefits
- Automatic barometric compensation reduces time required for post data processing
- Integrate into a third-party data collection system for remote real-time data
- Continuous, reliable water level data for long-term monitoring projects
- Actual water level readings for instant aquifer test results
Compatible with:
- Solinst Levelogger Software & App
- SDI-12, Modbus
- Levelogger App Interface
- DataGrabberâ„¢
AquaVent Specifications
AquaVent Datalogger | |
Level Sensor: | Piezoresistive Silicon with Hastelloy Sensor |
Accuracy: | ± 0.05% FS Typical |
Stability of Readings: | Superior, low noise |
Units of Measure: | m, cm, ft., psi, kPa, bar, ºC. ºF |
Normalization: | Automatic Temperature Compensation |
Temp. Comp. Range: | 0º to 50ºC |
Temperature Sensor: | Platinum Resistance Temperature Detector (RTD) |
Operating Temperature: | -20ºC to 80ºC |
Temp. Sensor Accuracy: | ± 0.05ºC |
Temp. Sensor Resolution: | 0.003°C |
Battery Life: | 8 Years – based on 1 reading/minute |
Clock Accuracy: | ± 1 minute/year (-20ºC to 80ºC) |
Thermal Response time: | 3-5 minutes |
Maximum # Readings: | 40,000 sets of readings in non-volatile FRAM memory (up to 120,000 in compressed mode) |
Memory: | Slate and Continuous |
Communication: | 9600 bps Solinst USB, 1200 baud SDI-12, Modbus RS-485/RS-232 (various speeds) |
Size: | 7/8″ x 7″ (22 mm x 178 mm) |
Weight: | 4.6 oz. (129 grams) |
Wetted Materials: | Delrin®, Viton®, 316L stainless steel, Hastelloy |
Sampling Modes: | Linear, Event & User-Selectable with Repeat Mode, Future Start, Future Stop, Real-Time View |
Measurement Rates: | 1/8 sec to 99 hrs |
Barometric Compensation: | Automatic |
Models | Full Scale (FS) | Accuracy |
M5 | 5 m (16.4 ft.) | ± 0.3 cm (0.010 ft.) |
M10 | 10 m (32.8 ft.) | ± 0.5 cm (0.016 ft) |
M20 | 20 m (65.6 ft) | ± 1 cm (0.032 ft.) |
AquaVent SP/SPX Wellhead | |
Materials: | Polypropylene, Delrin, 316 stainless steel, Viton, Polyamide |
Dimensions: | 4.0″ x 5.5″ (102 mm x 140 mm) |
Operating Temperature: | -20ºC to 80ºC |
IP Rating: | IP 64 (dust and splash proof) |
Batteries: | Four (4) 1.5V AA lithium batteries |
Wellhead Comm. Cable Length | 15 ft (4.5 m) |
AquaVent Vented Cable | |
Wetted Materials: | Polyurethane, 316 stainless steel, Viton |
Diameter: | Cable: 0.32″ (8 mm), Connectors” 0.86″ (22 mm) |
Lengths: | 1 to 500 ft |
Operating Temperature: | -20ºC to 80ºC |