OTT PLS-C

Pressure probe with conductivity measurement cell

Add to Request

The OTT PLS-C measures water conductivity, level, and temperature in both surface and groundwater applications with a robust ceramic pressure cell and 4-electrode conductivity cell. Its extremely low power consumption makes it ideal for long-term deployment, particularly at solar powered measuring stations for ground-and surface waters.

 

Outputs for conductivity include specific conductivity, salinity, and total dissolved solids

  • The robust ceramic pressure cell offers industry-leading accuracy and does not deform over time like membrane technology, providing long-term measurement stability
  • Rugged design: Ceramic pressure cell resistant to physical force (4 x burst pressure) and enclosure made of high-quality saltwater resistant steel for use in coastal environments
  • Vented pressure probe, automatically compensates for changes in barometric pressure
  • Robust cable with Kevlar core for length stabilization and capillary tube for venting
  • Built-in microcontroller – compensates for temperature effects and applies correction values for gravitational acceleration or water density
  • Simple setup and connection to external dataloggers using SDI-12

Water level, temperature, and conductivity measurement of:

  • Groundwater wells
  • Streams, rivers, channels, and canals
  • Reservoirs, lakes, and wetlands

Ideal for monitoring:

  • Continuous monitoring networks
  • Short-term or long-term projects
  • Salt water intrusion
  • Aquifer storage and recovery
  • Estuaries and wetlands

PLS-C Operating Instructions

PLS-C Datasheet

Output parameters Water level/pressure, temperature, specific conductivity, salinity, TDS
Water level measurement (pressure)
Pressure sensor ceramic, temperature-compensated
Measuring range 0 … 4 m, 0 … 10 m, 0 … 20 m, 0 … 40 m, 0 … 100 m water col.
Resolution 0.001 m; 0.1 cm; 0.01 ft; 0.1 mbar; 0.001 psi
Accuracy (linearity + hysteresis) ≤ ± 0.05 % FS
Long-term stability (linearity + hysteresis) ≤ ± 0.1 %/a FS
Zerodrift ≤ ± 0.1 % FS
Pressure sensor capability to withstand overloads without permanent mechanical damage ≥ 4 x measuring range
Temperature-compensated operating range -5 °C … +45 °C (ice free)
Units m, cm, ft, mbar, psi
Temperature measurement
Sensor NTC
Measuring range -25 °C … +70 °C (ice free)
Calibrated range +5 °C … 45 °C
Resolution 0.01 °C
Accuracy ±0.1 °C
Units °C, °F
Conductivity measurement
Sensor 4 graphite electrodes
Calibrated range +5 °C … 45 °C
Measuring range 5 … 2.000 µS/cm
Resolution 1µS/cm
Accuracy ±1 µS/cm or ± 0.5 % of measured value (whichever is higher)
Unit µS/cm
Measuring range 0.1 … 100 mS/cm
Resolution 0.01 mS/cm
Accuracy ± 0.01 mS/cm or ±1.5 % of measured value (whichever is higher)
Unit mS/cm
Options
Temperature compensation, conductivity freshwater, saltwater, standard method 2510, ISO 7888/EN27888
Salinity calculation Standard method or USGS 2311
Electrical data
Supply voltage 6 … 27 V DC, typically 12/24 V DC
Power consumption
SDI-12 sleep-mode <30 µAV
SDI-12 active-mode <32 mA
Interfaces SDI-12, RS-485 (SDI-12 protocol)
Mechanical data
Dimensions
Probe (Ø x h) 317 mm x 22 mm
Cable length SDI-12: 1 … 100 m
RS-485: 1 … 1000 m
Material
Housing material probe POM, stainless steel
(DIN 1.4539, 904 L ), resistant to sea water
Cable jacket PUR
Weight
Probe approx. 0.43 kg
Probe cable approx. 82 g/m
Ambient conditions
Storage temperature – 40 °C … + 85 °C
Type of protection Probe: IP 68
EMC limits EG 2004/108/EG, EN 61326-1:2013
Scroll to Top