In a world-first, a typical flow measuring application in a partially full, closed pipe is shown below. The MACE EchoFlo (mounted on the top of the pipe) measures the depth and a MACE Doppler sensor (2″ insert) measures velocity. Together, these two sensors are connected to a Series 3 FloPro that calculates, records and displays the resultant flow rate.
Key Benefits:
• Patented DSP technology – small dead band and beam width
• Compact, rugged design for deployment in applications with limited space and corrosive media
• Quick and easy configuration, no coding knowledge required
Range:
1.25m (49.2”) (+/- 0.24% Range)
2.5m (98.4”) (+/- 0.2% Range)
Resolution: 0.5mm (0.019”)
Beam width: 5cm (2”)
Dead band: 5cm (2”), 10cm (4”)
Supply voltage: 12-24 VDC
Consumption: 0.5W
Signal output: 0 – 5 V, 0 – 10 V, 976 – 2000 Hz
Frequency: Sink current = 15 mA nominal
Fail-safety: Full, empty, hold last
Configuration: EchoCal Software, USB 2.0
Temp. comp.: Automatic over range
Process temp.: C: -7˚ to 60˚
Ambient temp.: C: -35˚ to 60˚
Pressure: MWP = 206.8 kPa (30 PSI)
Enclosure: IP67 (Type 6P) encapsulated, corrosion resistant & submersible
Enclosure material: Polycarbonate
Strain relief material: Santoprene
Trans. material: PVDF
Cable length: 1.2 m (48”)
Cable jacket mat.: Polyurethane
Process mount: 1” NPT
Mount. gasket: Viton®
Classification: General purpose
Approvals: CE, cFMus
Ordering Information:
850-341 EchoFlo Ultrasonic Depth Sensor 1.25m
850-343 EchoFlo Ultrasonic Depth Sensor 2.5m