On-site Orthophosphate Analyser P 700 IQ

The P 700 IQ for orthophosphate measurement with the IQ SensorNet 2020XT continuous monitoring and control system.

The analyser enables the wet-chemical detection of orthophosphate directly in the plant process. This makes it the optimal solution for the support of phosphate elimination and for monitoring of phosphate in the plant effluent.

Add to Request

The P 700 for orthophosphate measurement can be used as a stand alone analyser or used with the IQ SensorNet 2020 XT continuous monitoring and control system. Use the P 700 throughout the wastewater plant from pre-sedimentation to biological tanks to the effluent. The P 700 provides continuous data to help operational efficiency improvement decisions and phosphate elimination verification.

-Compact design – pump for permeate supply is integrated in the analyser housing
-Simple system configuration with the IQ SensorNet; measure additional parameters in addition to orthophosphate
-Low reagent consumption – exchange solutions on average every 4-8 months, reduces overall cost vs. other analysers
-Automatic or manual calibration (adjustable)
-Uses proven Vanadomolybdate (yellow) method of detection
-Wide measuring range – two measuring ranges allow the P700 to be used in a wide range of locations throughout the WWTP
-Indoor or outdoor versions available with heating or cooling

P 700 IQ Technical Specifications
Measurement Methods Vanadomolybdate (yellow)
Measurement Range PO4-P Range A: 0.05 to 15.00 mg/L; Range B: 1 to 50 mg/L
Resolution PO4-P Range A: 0.01 mg/L; Range B: 1 mg/L
Accuracy PO4-P Range A: ±2% or ±0.05 mg/L, whichever is greater; Range B: ±2% or ±1 mg/L, whichever is greater
Measurement Range PO4 Range A: 0.15 to 46.00 mg/L; Range B: 3 to 153 mg/L
Resolution PO4 Range A: 0.01 mg/L; Range B: 1 mg/L
Accuracy PO4 Range A: ±2% or ±0.15 mg/L, whichever is greater; Range B: ±2% or ±3 mg/L, whichever is greater
Response Time T-90 < 5 minutes
Detection Limit Range A: 0.05 mg/L PO4-P; Range B: 1 mg/L PO4-P
Calibration Automatic (adjustable) or manual
Dimensions ~26.69 x 30.71 x 15.55 in (~678 x 780 x 395 mm)
Weight ~66 lbs (~30 kg); without reagents
Measuring Interval Range A: 5 minutes (adjustable) or greater; Range B: 10 minutes or greater
Cleaning Solution 1,000 mL for 4 months with cleaning every 24 hours
Climate Control Heating, Cooling (fan)
pH Range 5 to 9 pH units
Operating Temperature -20 to 40ºC (-4 to 104°F)
Storage Temperature -20 to 50ºC (-4 to 122°F)
Sample Temperature 4 to 45ºC (39 to 113°F)
Reagent Consumption
2500 mL for 8 months with measuring range A and 10 minute measuring interval
2500 mL for 4 months with measuring range B and 10 minute measuring interval
Equipment Safety, Standards EN 61010-1; UL 3111-1; CAN/CSA C22.2 No. 61010.1
Electrical 115 VAC
Certifications CE, IP54, UL, cETLus
Outputs Relays, analog outputs, various communication protocols, interfaces directly with IQ SensorNet 2020 XT (not compatible with Model 182)

Ordering Guide
Item # Description
8P-000Y P 700 IQ-I115 Orthophosphate analyser P 700 IQ, indoor, 115 V (power supply not included)
8P-001Y P 700 IQ-O115 Orthophosphate analyser P 700 IQ, outdoor for climate control, 115 V (power supply not included)
821 972Y Set of 2 filter membranes for filter membrane module (821987Y) and module case (821973Y)
821 973Y Module case for filter membranes. Includes module case without filter membranes (order filter membranes separately)
821 974Y Permeate return line, unheated, 6.5 ft (2 m)
821 976Y Permeate return line, heated, 230 VAC, 6.5 ft (2 m)
821 977Y Suction tube with slide, unheated, 33 ft (10 m)
821 978Y Suction tube with slide, unheated, 16.2 ft (5 m)
821 980Y Suction tube with slide, heated, 230 VAC, 33 ft (10 m)
821 982Y Suction tube with slide, heated, 230 VAC, 16.2 ft (5 m)
821 983Y Adapter for horizontal mounting of filter membrane module FM
821 984Y Cleaning case for filter membranes
821 985Y Extension for attachment. Included: extension 4.9 ft (1.5 m), chain, bracket
821 986Y Attachment for filtration. Included: rail 4.9 ft (1.5 m), chain, bracket
821 987Y Filter membrane module with pre-mounted membrane
821 970Y Bottle top with tube for standards
821 971Y Standard solution 0.0 mg/L PO4-P (zeroing) for P 700 IQ (1.0 L)
821 988Y Rail mount for P 700 IQ
821 989Y Wall mount for P 700 IQ
821 990Y Replacement LED for photometer unit
821 991Y Stand mount for P 700 IQ
821 992Y Set of replacement parts (fittings and psare tubes) for P 700 IQ
821 993Y Replacement pump tube
821 994Y Replacement pump motor for peristaltic pump
821 995Y Standard solution 20.0 mg/L PO4-P for P 700 IQ (1.0 L)
821 996Y Standard solution 8.0 mg/L PO4-P for P 700 IQ (1.0 L)
821 997Y Standard solution 1.6 mg/L PO4-P for P 700 IQ (1.0 L)
821 998Y Cleaning solution for P 700 IQ (1.0 L)
821 999Y Reagent for P 700 IQ for orthophosphate measurement (2.5 L)

wtw-phosphate-analyzerp7002015

Weight 10 kg
Scroll to Top