AmmoLyt® Plus

AmmoLyt® Plus low investment costs can thus be amortised after a short period.

The AmmoLyt ammonium sensor and the AmmoLyt combination electrode together with the IQ SENSOR NET system form a measuring system that is protected to a high degree against low and high frequency interference as well as against the indirect effects of lightning strikes.

Add to Request

Wastewater treatment processes are concerned with controlling the energy efficient removal of pollutants in the smallest possible space in the shortest possible time.

The AmmoLyt® ammonium sensor forms a measuring system for the online determination of ammonium ions. It supplements the oxygen measurement in the aeration tank and enables a more efficient aeration control.

The AmmoLyt® ammonium sensor, in conjunction with the AmmoLyt ammonium combination electrode, is suitable for stationary ammonium measurements in water/wastewater applications.

Ammonium Measurement directly in the Medium – without Sample Preparation. The continuous measuring of O2 and NH4 can result in significant savings through:
•Energy-optimised operation due to demand-oriented regulation of aerator aggregates,
• Adherence to critical values or reduction of wastewater charges.
• The potassium measuring value can be displayed optionally.

Ammonium Measurement Appropriate Electrodes
Reference Electrode VARiON®Plus Ref
Measuring Electrode VARiON®Plus NH4
Compensation Electrode VARiON®Plus K

Measuring Ranges/Resolution
NH4-N:
1 to 1000 mg/l / 1 mg/l;
0.1 to 100 mg/l / 0.1 mg/l

NH4+:
1 to 1290 mg/l / 1 mg/l;
0.1 to 129.0 mg/l / 0.1 mg/l

Compensation Ranges K+:
1 to 1000 mg/l / 1 mg/l

Temperature Measurement and Compensation
Integrated NTC thermistor,
Range 0 °C to +40 °C,
Accuracy: ±0,5 K
Resolution: 0,1 K, t95 < 20 s

Ordering Information:

AmmoLyt® Plus Sets and Standard Solutions
107 070 AmmoLyt® Plus 700 IQ Robust digital ammonium probe for ion-selective electrodes (in-situ measuring), for use with the IQ SENSOR NET system. With built-in lightning protection, pre-amplifier and temperature sensor. Not included: Electrodes VARiON® Ref, VARiON®Plus NH4, VARiON®Plus K and SACIQ connection cable (Please order separately).

107 071 AmmoLyt® Plus SET Robust digital ammonium probe for ion-selective electrodes (in-situ measuring), for use with the IQ SENSOR NET system, delivered with VARiON® Ref and VARiON®Plus NH4 electrodes. With built-in lightning protection, pre-amplifier and temperature sensor. Not included: Electrode VARiON®Plus K and SACIQ connection cable (Please order separately).

107 072 AmmoLyt® Plus SET/Comp Robust digital ammonium probe for ion-selective electrodes (in-situ measuring), for use with the IQ SENSOR NET system, delivered with VARiON® Ref, VARiON®Plus NH4 and VARiON®Plus K electrodes. With built-in lightning protection, pre-amplifi er and temperature sensor. Not included: SACIQ connection cable (Please order separately).

107 050 VARiON®/ES-1 Multiple standard solution 1 (low concentration) for VARiON®Plus 700 IQ/ AmmoLyt®Plus 700 IQ/NitraLyt®Plus 700 IQ; Volume: 1000 ml

107 052 VARiON®/ES-2 Multiple standard solution 2 (high concentration) for VARiON®Plus 700 IQ/AmmoLyt®Plus 700 IQ/NitraLyt®Plus 700 IQ; Volume: 1000 ml

AmmoLyt® Plus 700 IQ Accessories
107 042 VARiON® Ref Reference electrode for mounting into VARiON®Plus 700 IQ, NitraLyt® Plus, AmmoLyt®Plus probe

107 044 VARiON®Plus NH4 Ammonium electrode for VARiON®Plus 700 IQ and AmmoLyt®Plus/AmmoLyt®, Measuring range: 0.1 – 1000 mg/l NH4-N

107 046 VARiON®Plus K Potassium electrode for VARiON®Plus 700 IQ and for AmmoLyt®Plus, Measuring range: 1 – 1000 mg/l K+

107 004 AmmoLyt® 700 IQ Accessories (Sensor not available any more, replaced by AmmoLyt®Plus 700 IQ) AmmoLyt® NHA Reference electrode for on-line measuring of ammonium, with armouring for mounting into AmmoLyt® 700 IQ probes (Attention: not for AmmoLyt®Plus!)

107 016 AmmoLyt® 700 IQ-SK Protection device for ISE electrode mountable on AmmoLyt® 700 IQ and NitraLyt® 700 IQ (Attention: not for AmmoLyt®Plus or NitraLyt®Plus!)

107 044 AmmoLyt® NHA/AT replaced by VARiON®Plus NH4 VARiON®Plus NH4 Ammonium electrode for VARiON®Plus 700 IQ and AmmoLyt® Plus/AmmoLyt®, Measuring range: 0.1 – 1000 mg/l NH4-N