Beacon 110 Single Channel Wall -Mount Controller

Gas detection should not be complicated. The Beacon 110 is gas detection simplified.

The Beacon 110 is a powerful, low cost fixed system controller for one point of gas detection. It is microprocessor controlled, versatile, simple to install and operate, and priced to be the industry’s best value single gas detection controller. It is capable of accepting RKI sensors directly for LEL level combustibles, Oxygen, Hydrogen Sulfide, or Carbon Monoxide. The Beacon 110 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC). Sensors can be mounted directly at the Beacon 110 housing, or can be wired remote from the controller.

Add to Request

The Beacon 110 is a fixed mount, single channel continuous-monitoring gas monitoring controller. All user adjustable parameters may be accessed using push button switches. Both direct connect (internal amplifier type) detector heads and 4 – 20 mA transmitter (remote amplifier type) detector heads may be used with the Beacon 110.

Features
• Low cost versatile solution
• 115/220 VAC or 24 VDC operation
• Long life sensors (2+ years typical)
• Accepts any 4-20 mA transmitter
• Audible alarm with reset button
• Two programmable alarm levels
• Built-in trouble alarm with relay
• Accepts RKI LEL/O2/H2S/CO direct connect sensors
• Relay rating 10 amps, form C
• Provides 4-20 mA output
• Compact, weatherproof, NEMA 4X enclosure

The Beacon 110 displays the current gas reading on an LCD display which is visible through a window in the door. It includes audible and visual alarms that warn you of hazardous gas conditions. The alarm circuit includes two levels of gas alarms. The fail circuit alerts you to failures in the gas detector heads or Beacon 110. The Beacon 110 provides a 4 – 20 mA signal proportional to the target gas reading for use by a recording device. Three sets of relay contacts, two controlled by the gas alarms and one by the fail alarms are available for controlling devices such as lights or horns or for controlling higher rated relays.

Three operating modes allow you to display and change set-up and calibration settings and change the detector head input type: Calibration Mode, Configuration Mode, and Input Mode.

The 10 amp rated relays are strong enough to directly power external alarms and horns. The digital display has backlighting and simultaneous readout of the gas type and concentration.

The Beacon 110 is also housed in a NEMA 4X rated case for a weather tight seal. This case design complies with lock out / tag out standards and can be fully secured. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 110 ships complete with a wall mounting kit for easy installation.

RKI offers the industry’s widest selection of standard and toxic gas detection sensors, which can be utilised with the Beacon 110, providing gas monitoring protection for almost any application.

Applications
• Petrochemical plants
• Refineries
• Water & wastewater treatment pants
• Pulp & paper mills
• Gas, telephone, & electric utilities
• Parking garages
• Manufacturing facilities
• Steel
• Automotive
• HVAC

SPECIFICATIONS
Sampling Methods Diffusion and sample draw heads available.
Inputs
Direct Wired Sensors LEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide
Remote amp not required for less than 500 feet.
4-20 mA Sensors Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals

Outputs
Relays 3 relays – 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarms and 1 trouble relay. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energised or normally de-energised, time delay for alarm on and alarm off
4-20 mA Signal output, 4-20 mA (maximum load impedance 500 ohms), per channel
24 VDC 24 VDC (400 mA max) output provided to operate sample drawing adapters or other accessories

Display 2 x 8 Alphanumeric display with back-lighting.
Audible Built-in audible alarm, 94 dB, mounted on enclosure
Coded output: pulsing = gas alarm, steady = fail
Visual 3 LED’s on the front cover for alarm status indication, and malfunction

Warranty One year materials and workmanship

Ordering Information:

When ordering a Beacon 110 system, please specify the following components:
1) Controller
2) Detector Assembly (one only)
Note; The Beacon 110 can accept direct connect sensors for LEL combustibles (catalytic or IR sensor), Oxygen, Hydrogen Sulfide , Carbon Monoxide , and Carbon Dioxide as well as other gases (see Direct Connect Sensor section for a complete listing on page 89. The Beacon 110 can also accept any 4-20 mA transmitter.

72-2110RK Beacon 110, single channel controller (no sensor)
72-2110RK-01 Beacon 110, single channel controller with battery charger (no sensor)
72-2110RK-02 Beacon 110, single channel controller with strobe light (no sensor)
72-2110RK-03 Beacon 110, single channel controller with battery charger and strobe light (no sensor)

Explosion Proof Sensors, No J-Box
61-0140RK Sensor, LEL combustible (catalytic), direct connection (no transmitter, no j-box), UL version
NC-6234-01 Sensor, LEL Hydrogen (H2) specific, 1/2 NPT, with guard, direct connection (no transmitter, no j-box),UL version
61-0190RK-CH4 Sensor, IR, Methane (CH4) 0 – 100% LEL, explosion proof direct connection (no transmitter, no j-box), UL version
61-0190RK-HC Sensor, IR, Hydrocarbon (HC) 0 – 100% LEL, isobutane standard calibration, explosion proof direct connection (no transmitter, no j-box), UL version
61-0192RK-CH4 Sensor, IR, Methane (CH4) 0 – 100% volume, explosion proof direct connection (no transmitter, no j-box),UL version
61-0191RK-02 Sensor, IR, Carbon Dioxide (CO2) 0 – 5,000 ppm, explosion proof direct connection (no transmitter, no j-box), UL version
61-0191RK-03 Sensor, IR, Carbon Dioxide (CO2) 0 – 5%, explosion proof direct connection (no transmitter, no j-box),UL version
61-0191RK-05 Sensor, IR, Carbon Dioxide (CO2) 0 – 50%, explosion proof direct connection (no transmitter, no j-box), UL version
61-0191RK-10 Sensor, IR, Carbon Dioxide (CO2) 0 – 100%, explosion proof direct connection (no transmitter, no j-box),UL version

61-0140RK-05 Sensor, LEL combustible (catalytic), direct connection (no transmitter, no j-box), CSA version
65-2514RK Sensor, Oxygen (O2), capillary type, explosion proof, (no transmitter, no j-box), CSA version
65-2433RK-05 Sensor, Carbon Monoxide (CO), direct connection (no transmitter, no j-box), CSA version
65-2423RK-05 Sensor, Hydrogen Sulfide (H2S), direct connection (no transmitter, no j-box), CSA version

Non Explosion Proof Sensors, No J-box
65-2494RK Sensor, Oxygen (O2) 0 – 25%, non explosion proof direct connect, capillary type, no j-box
65-2510RK Sensor, Oxygen (O2) 0 -25%, non explosion proof direct connect, partial pressure type
(no transmitter, no j-box)
65-2495RK Sensor, Hydrogen Sulfide (H2S) 0 – 100 ppm, non explosion proof direct connect, no j-box
65-2496RK Sensor, Carbon Monoxide (CO) 0 – 300 ppm, non explosion proof direct connect, no j-box
61-0198RK-02 Sensor, IR Carbon Dioxide (CO2) 0-5,000 ppm, non explosion proof direct connect, replaceable sensor
61-0198RK-03 Sensor, IR Carbon Dioxide (CO2) 0-5%, non explosion proof direct connect, replaceable sensor
61-0198RK-05 Sensor, IR Carbon Dioxide (CO2) 0-50%, non explosion proof direct connect, replaceable sensor
61-0198RK-10 Sensor, IR Carbon Dioxide (CO2) 0-100%, non explosion proof direct connect, replaceable sensor

Explosion Proof Sensors, With J-box
61-1000RK Sensor, LEL combustible (catalytic) with explosion proof j-box (no transmitter), UL version
61-1004RK-02 Sensor, IR, Carbon Dioxide (CO2) 0 – 5,000 ppm, explosion proof with j-box, UL version
61-1004RK-03 Sensor, IR, Carbon Dioxide (CO2) 0 – 5%, explosion proof with j-box, UL version
61-1004RK-05 Sensor, IR, Carbon Dioxide (CO2) 0 – 50%, explosion proof with j-box, UL version
61-1004RK-10 Sensor, IR, Carbon Dioxide (CO2) 0 – 100%, explosion proof with j-box, UL version
61-1001RK Sensor, LEL Hydrogen (H2) specific with explosion proof j-box (no transmitter), UL version
61-1003RK-CH4 Sensor, IR, Methane (CH4) 0 – 100% LEL, explosion proof with j-box, UL version
61-1003RK-HC Sensor, IR, Hydrocarbons (HC) 0 – 100% LEL, isobutane standard calibration, explosion proof with j-box, UL version
61-1006RK-CH4 Sensor, IR, Methane (CH4) 0 – 100% VOL, with j-box, UL version

61-1000RK-05 Sensor, LEL combustible (catalytic) with explosion proof j-box (no transmitter), CSA version
65-2515RK Sensor, Oxygen (O2), capillary type, explosion proof with conduit mounting and j-box (no transmitter), CSA version
65-2437RK-05 Sensor, Carbon Monoxide (CO) with j-box, CSA version
65-2427RK-05 Sensor, Hydrogen Sulfide (H2S) with j-box, CSA version

Non Explosion Proof Sensors, With J-box
65-2497RK Sensor, Oxygen (O2) 0 – 25%, direct connect, capillary type, non explosion proof, with j-box
65-2502RK Sensor, Oxygen (O2) with j-box and I.S. barrier, partial pressure type, (no explosion proof approval)
65-2498RK Sensor, Hydrogen Sulfide (H2S) 0 – 100 ppm, direct connect, non explosion proof, with j-box
65-2499RK Sensor, Carbon Monoxide (CO) 0 – 300 ppm, direct connect, non explosion proof, with j-box
61-1007RK-02 Sensor, IR, Carbon Dioxide (CO2) 0 – 5,000 ppm, non explosion proof with j-box
61-1007RK-03 Sensor, IR, Carbon Dioxide (CO2) 0 – 5%, non explosion proof with j-box
61-1007RK-05 Sensor, IR, Carbon Dioxide (CO2) 0 – 50%, non explosion proof with j-box
61-1007RK-10 Sensor, IR, Carbon Dioxide (CO2) 0 – 100%, non explosion proof with j-box

beacon110-spec-sheet

beacon110-manual

Weight 10 kg
Scroll to Top