- Realtime detection of up to 5 ranges for combustible gas, 100%vol./ 100%LEL, O2, H2S, and CO
- Large simultaneous display with auto back lighting
- Strong sample drawing capability
- Loud alarm buzzer with 95dB
- 3 bright LED alarm lamps
- ATEX Exia II CT4 approved
- Water and dust resistant IP67
- Lithium-ion rechargeable battery
- Compact and light weight
- Ergonomic design with wrist strap for hands free operation
- Datalogging standard
GX-8000
The GX-8000 Sample Draw Gas Monitor sets the new industry standard for rugged, reliable portable gas detection. It’s tough, water proof design utilized features based on years of gas detection design experience, to assure that the instrument will operate properly to protect workers and property in all kinds of harsh gas detection applications.
- Confined Space Entry
- Refineries, Petrochemical, Chemical Plants
- Oil Tanker, Gas Carrier, Bulk Carrier
- Chemical Tanker
- Wastewater Treatment
- Fire Services
- Telecommunication Services
- Power Plants
- Gas Plant, Gas Supplier Services
- Utilities
- Coating Field
- Fuel Cell Facilities
Target gas | Combustibles (CH4 , i-C4H1O , H2 , others) |
Oxygen (02) |
Hydrogen Sulfide (H2S) |
Carbon Monoxide (CO) |
|
---|---|---|---|---|---|
Detection principle | Thermal Conductivity | Catalytic Combustion | Galvanic cell | Electrochemical | Electrochemical |
Detection range (increments) |
0-100 vol% (1%vol) |
0-100 LEL% (1%LEL) |
0-40.0%vol (0.1%) |
0-100.0ppm (0.5ppm) |
0-500ppm (1ppm) |
Gas alarm | N/A | 1st : 10%LEL 2nd: 50%LEL |
1st : 19.5% 2nd: 23.5% |
1st : 10.0ppm 2nd: 30.0ppm TWA: 10.0ppm STEL: 15.0ppm |
1st : 25ppm 2nd: 50ppm TWA: 25ppm STEL: 200ppm |
Types of alarm | Gas alarm : Latching, 2 alarms Failure alarm: Flow failure, Sensor failure, Battery failure, Circuit failure, Calibration failure |
||||
Display of alarm | LED: -Flashing LED’s Buzzer:: -Buzzer sounds alternates between a low and high pitch Visual display: -Indication value flashes. Alarm message displays and flashes. |
||||
Alarm sound | More than 95dB (A) at 30cm | ||||
Display | Digital LCD with auto backlight Digital display (7 segments) and digital bar graph (25 segments) (50 segments with single gas versions GX-8000 Type LEL & Type O2) |
||||
Sampling method | Sample Draw, Minimum 0.75L/min | ||||
Power source | Lithium-ion battery as standard (fully charged in 3 hours) Optional 3pcs AA alkaline battery pack also available (Alkaline battery pack standard with single gas versions: GX-8000 Type O2 / GX-8000 Type LEL -Lithium-ion battery optional) |
||||
Continuous operation | Lithium-ion battery: more than 12 hours (GX-8000 Type O2, more than 20 hours) AA alkaline battery pack: more than 6 hours (GX-8000 Type O2, more than 12 hours) |
||||
Operating temp & humidity | -20~+50°C, -4-+122°F below 95%&RH (Non-condensing) | ||||
Dimensions & Weight | Approx. 154(W) x 81(H) x 127(D) mm, Approx. 1.1kg with Lithium ion battery (Alkaline battery 0.9kg) Approx. 6.1″(W) x 3.1″(H) x 4.9″(D), Approx. 2.4lb with Lithium ion battery (Alkaline battery 2.0lb) |
||||
Ingress proof rating | IP67 | ||||
Explosion proof | Intrinsically safe Exia II CT4 | ||||
Approvals | IECEx, ATEX, MED (Wheel Mark), CE, TIIS, HK | ||||
Additional features | Activity indicator (pilot indicator and pump driving indicator), Pump stop function, Bump test function, IrDA communication, Data logger, Password protection (GX-8000 single gas versions Type LEL & Type O2 with confidence beep and LED flash (once every minute) |